Hard Facts

Our state-of-the-art data centre, with three physically separate external connections via distinct routes, enables us to guarantee our customers 99.9 per cent uptime. The data centre has two separate fire compartments, which also allow for the operation of cluster systems spanning multiple fire compartments.

With our housing and Colocation packages, you can choose from options ranging from 1U in a single-housing rack right up to a full Colocation rack with 42U. Our 24/7 Remote Hands Service is provided by qualified service staff.

Thanks to our early fire detection system, we can guarantee the safe operation of your servers even in the event of a fire. Below you will find all the technical specifications for our housing and Colocation packages:

Housing & Racks

Rack

  • 19" 42U racks (H/W/D) = 800 mm x 2000 mm x 800 mm
  • 19" racks
  • 42U racks

Electricity

  • 2 x 16 A power strips (on both sides)
  • 2 x Backmann 16 A power strips, each with 24 x C13 IT plugs
  • Maximum power consumption 3.5 kW per rack

Network

  • Redundant multi-mode LC 10 Gbit/s (1 Gbit/s) uplink per rack
    • Single-mode available for cross-fire-compartment redundancy (no external connection)
  • Existing private VLANs can be included in centron and Colocation packages
  • Cross-fire-compartment fibre-optic cross-connect (optional)
  • 10 Gbit via fibre per rack (optical) (optional)
    • Can optionally be limited to 1 Gbit per rack
  • Dedicated IPv6 and IPv4 address blocks with RIPE
  • Separate VLAN with its own IP address range possible

Multimode is the standard for all centron Datacentre short-range connections. To set up a fibre-optic connection using an LC connector, you will need a switch equipped with GBIC (Gigabit Interface Converter) modules.

Connections

  • 6 x 10 Gbit (redundant)
  • Multicarrier connection

Electricity and emergency power supply

  • 1.25 megawatts (redundant)
  • 2 separate power feeds spanning fire compartments
  • Redundant, energy-efficient UPS system with 2 hours’ runtime
  • 1,200 kVA diesel generator
  • PUE below 1.2
  • Redundant power supply via two power feeds

Security

  • Alarm-protected building complex with different security zones
  • 24/7 surveillance, alarm-protected
  • Perimeter surveillance
  • Biometric, electronic and logged access control based on an access list

Air conditioning

  • Redundant 600 kW N+1 air conditioning
  • Direct free cooling
  • Min. 3.5 kW cooling capacity per rack
  • Cold aisle containment with redundant air conditioning system (600 kW cooling capacity)

Data centre floor space

  • 600 m²
  • 2 separate fire compartments
  • Private cages

Data Centre Features

  • 3 physically separate external connections, each with its own cable route
  • Redundant core infrastructure spanning fire compartments
  • Cable management
    • red = public (WAN)
    • green = private (LAN)
    • white = IPMI
    • yellow = POE

Each of your devices is assigned a unique ID before the installation date, which means it can be identified immediately and linked to your account.

Should you require staff support for the operation of your systems, dedicated centron technicians and administrators are on hand to assist you. centron also offers optimal solutions for the temporary use of office and data centre space.

We would be happy to provide you with a quote tailored to your needs. With the centron Data Centre, which is certified to ISO 27001 and ISO 9001, you’re in safe hands.